View changes for revision:                                          
P Switch from Brick Block (88, rev. 5)
By  MeroMero on 05-03-15, 08:52 pm
Category 'Event controllers', known, fully documented
(no description)
Data files: none
Sprite fields:
Output ID: value at nybble 2-3. 0=disable.
Output mode: list at nybble 8: 0=Start ID activation,1=Stop ID activation. Activation has to be started/enabled. Can toggle once started or ended by hitting the opposite sw. again
Input ID: value at nybble 0-1. 0=disable.
Input mode: list at nybble 9: 0=One time use,1=Toggle start/stop,2=Toggle input/output. Timer mode automatically resets switch to opposite output mode. Or it can be reset by another switch. With no timer, a start/stop toggle will respawn when you leave then return to the screen.
Timer mode: list at nybble 6: 0=Timer with music,1=No timer no music. When timed, switch starts in start or stop. While timed, it is opposite.
Time out sw. delay: value at nybble 5. In seconds, Only delays multiple on/off hits
Affected by gravity: checkbox at nybble 4 with mask 1
Upside down: checkbox at nybble 11 with mask 1. When hit, an upside down P-switch will appear in the place where the brick block was.
Brick Block that contains P Switch (88, rev. 6)
By  Hiccup on 05-04-15, 10:54 am
Category 'Event controllers', known, fully documented
(no description)
Data files: none
Sprite fields:
Output ID: value at nybble 2-3. 0=disable.
Output mode: list at nybble 8: 0=Start ID activation,1=Stop ID activation. Activation has to be started/enabled. Can toggle once started or ended by hitting the opposite sw. again
Input ID: value at nybble 0-1. 0=disable.
Input mode: list at nybble 9: 0=One time use,1=Toggle start/stop,2=Toggle input/output. Timer mode automatically resets switch to opposite output mode. Or it can be reset by another switch. With no timer, a start/stop toggle will respawn when you leave then return to the screen.
Timer mode: list at nybble 6: 0=Timer with music,1=No timer no music. When timed, switch starts in start or stop. While timed, it is opposite.
Time out sw. delay: value at nybble 5. In seconds, Only delays multiple on/off hits
Affected by gravity: checkbox at nybble 4 with mask 1
Upside down: checkbox at nybble 11 with mask 1. When hit, an upside down P-switch will appear in the place where the brick block was.