View changes for revision:                                                                                                                                                                                          
? Switch (107, rev. 17)
By  Hiccup on 10-19-14, 11:08 am
Category 'Event controllers', known
(no description)
Data files:
• /obj/I_switch_ncg.bin
Sprite fields:
Triggering Event ID: value at nybble 0-1. 0=Ignore input ID, other value will wait for ID
Target Event ID: value at nybble 2-3
Settings: list at nybble 4: 0=None,1=Falls,4=Loads at Midway only,8=No Music Interrupt. If 8 is chosen, the Music will not be interrupted when the Switch is pressed.
Delay on Multi Use: list at nybble 5: 0=Instantaneous (No Delay),2=Short Delay,3=Long Delay,1=Very Long Delay. In seconds. Only delays multiple on/off hits
Non-Timed Event: checkbox at nybble 6 with mask 1
Switch Mode: Deactivates Target: checkbox at nybble 8 with mask 1
Usage Mode: list at nybble 9: 0=(0) Single Use,1=(1) Multi Use,2=(2) Broken on/off function (Unused). Timer mode automatically resets switch to opposite output mode. Or it can be reset by another switch. With no timer, a start/stop toggle will respawn when you leave then return to the screen.
Shift ½ right: checkbox at nybble 10 with mask 1
Upside Down: checkbox at nybble 11 with mask 1. If this is checked, the Switch will be facing down. Upside down Switches cannot fall.
? Switch (107, rev. 18)
By  Hiccup on 10-19-14, 11:10 am
Category 'Event controllers', known
(no description)
Data files:
• /obj/I_switch_ncg.bin
Sprite fields:
Triggering Event ID: value at nybble 0-1. 0=Ignore input ID, other value will wait for ID
Target Event ID: value at nybble 2-3
Settings: list at nybble 4: 0=None,1=Falls,4=Loads at Midway only,8=No Music Interrupt (Does this exist/work?). If 8 is chosen, the Music will not be interrupted when the Switch is pressed.
Delay on Multi Use: list at nybble 5: 0=Instantaneous (No Delay),2=Short Delay,3=Long Delay,1=Very Long Delay. In seconds. Only delays multiple on/off hits
Non-Timed Event: checkbox at nybble 6 with mask 1
Switch Mode: Deactivates Target: checkbox at nybble 8 with mask 1
Usage Mode: list at nybble 9: 0=(0) Single Use,1=(1) Multi Use,2=(2) Broken on/off function (Unused). Timer mode automatically resets switch to opposite output mode. Or it can be reset by another switch. With no timer, a start/stop toggle will respawn when you leave then return to the screen.
Shift ½ right: checkbox at nybble 10 with mask 1
Upside Down: checkbox at nybble 11 with mask 1. If this is checked, the Switch will be facing down. Upside down Switches cannot fall.